Your privacy, your choice

We use essential cookies to make sure the site can function. We also use optional cookies for advertising, personalisation of content, usage analysis, and social media.

By accepting optional cookies, you consent to the processing of your personal data - including transfers to third parties. Some third parties are outside of the European Economic Area, with varying standards of data protection.

See our privacy policy for more information on the use of your personal data.

for further information and to change your choices.

Skip to main content

Table 2 A comparison of doses to the heart and ipsilateral lung dosimetry from the MammoSite catheter and external beam radiotherapy using the radiobiologically adjusted dosimetric parameters.

From: Dose volume histogram analysis of normal structures associated with accelerated partial breast irradiation delivered by high dose rate brachytherapy and comparison with whole breast external beam radiotherapy fields

MammoSite (34 Gy/10#/1 week)

External Beam (50 Gy/25#/5 weeks)

p-value

Mean

Range

Mean

Range

 

Lung

    

V23.5 7 cc

0–20.4 cc

V30 86.7 cc

31.5–184 cc

p = 0.05*

V23.5 0.7%

0–1.5%

V30 8.3%

2.3–19.9%

p = 0.03*

V16.5 23.6 cc

0–57.9 cc

V20 105 cc

46.1–205 cc

p = 0.06

V16.5 2.3%

0–4.2%

V20 10%

3.3–22.2%

p = 0.03*

V9 98.1 cc

0–201.7 cc

V10 133.6 cc

67.8–235 cc

p = 0.48

V9 9.4%

0–13.3%

V10 12.8%

4.9–25.4%

p = 0.26

Heart

    

V16.5 1.2 cc

0–5.2 cc

V20 15.7 cc

0–23.9 cc

p = 0.009*

V16.5 0.3%

0–1.2%

V20 3.7%

0–5.3%

p = 0.01*

V9 15.9 cc

2.1–47.4 cc

V10 22.9 cc

0.3–39.0 cc

p = 0.34

V9 3.7%

0.5–10.5%

V10 5.4%

0.1–8.7%

p = 0.35

V4.5 105.7 cc

64.5–173.5 cc

V5 41.47 cc

3.1–82.3 cc

p = 0.001*

V4.5 25.0%

15.1–38.5%

V5 9.6%

0.8–18.3%

p = 0.002*

  1. * represents a statistically significant p-value