DVHs for HN4 (top) for VMAT (solid line) and DTRT (dashed line). Dose distribution from Eclipse and corresponding gamma maps (2%/2 mm, threshold: 10% of maximum dose) comparing film dose to AAA-calculated dose in Eclipse for DTRT for both dose levels (bottom)