Table 3 Mean DSC between the ground truth (csPCa-Histo) segmentation and the predicted segmentation (csPCa-CNN and csPCa-AI-Rad) for various networks

From: Comparison of data fusion strategies for automated prostate lesion detection using mpMRI correlated with whole mount histology

Network

Input Data

Fusion

Mean DSC

UNet

T2W only

 

0.14 ± 14

ADC only

0.25 ± 20

High b-Value only

0.28 ± 21

mpMRI & parametric clinical data

EF

0.30 ± 0.23

IF

0.34 ± 0.26

LF

0.36 ± 0.24

mpMRI only

EF

0.26 ± 0.22

IF

0.33 ± 0.23

LF

0.34 ± 0.26

RADAI

mpMRI only

EF

0.31 ± 0.21