Skip to main content

Table 6 Mean value and range of CTV dosimetric parameters absolute between the original and perturbed DIBH and FB treatments

From: Reproducibility and stability of voluntary deep inspiration breath hold and free breath in breast radiotherapy based on real-time 3-dimensional optical surface imaging system

Volume

Parameters

DIBH

FB

DIBHorg

DIBHmin

DIBHmax

p value

FBorg

FBmin

FBmax

p value

p1

p2

p1

p2

CTV

D95 (Gy)

40.10 ± 1.36

39.78 ± 0.86

40.17 ± 0.79

 < 0.05

 < 0.05

40.52 ± 0.19

38.46 ± 1.76

40.76 ± 0.31

 < 0.05

 < 0.05

D98 (Gy)

39.10 ± 1.06

38.59 ± 1.36

39.17 ± 1.09

 < 0.05

 < 0.05

40.09 ± 0.22

36.54 ± 2.79

40.05 ± 0.48

 < 0.05

0.795

D99 (Gy)

38.37 ± 1.26

37.50 ± 2.03

38.50 ± 1.28

 < 0.05

0.097

39.79 ± 0.30

35.13 ± 3.28

39.54 ± 0.59

 < 0.05

0.173

Dmean (Gy)

42.42 ± 0.14

42.26 ± 0.19

42.82 ± 0.31

 < 0.05

 < 0.05

43.44 ± 1.0

42.75 ± 1.01

44.02 ± 1.23

 < 0.05

 < 0.05

D2 (Gy)

43.69 ± 0.15

43.98 ± 0.40

45.31 ± 0.72

 < 0.05

 < 0.05

49.27 ± 2.68

48.67 ± 2.52

50.79 ± 3.17

 < 0.05

 < 0.05

Dmax (Gy)

44.11 ± 0.18

44.52 ± 0.55

46.19 ± 0.57

 < 0.05

 < 0.05

50.54 ± 2.77

49.90 ± 2.66

53.11 ± 3.67

 < 0.05

 < 0.05

D50 (Gy)

42.75 ± 0.14

42.32 ± 0.14

43.09 ± 0.30

 < 0.05

 < 0.05

42.43 ± 0.86

41.95 ± 0.95

43.06 ± 1.07

 < 0.05

 < 0.05

CI

0.67 ± 0.07

0.49 ± 0.09

0.61 ± 0.06

 < 0.05

 < 0.05

0.67 ± 0.12

0.65 ± 0.08

0.72 ± 0.09

 < 0.05

 < 0.05