Skip to main content

Table 2 Dosimetric analysis of the actual doses received by OARs when utilizing LRT as a boost plan in comparison to CRT

From: Deep learning-based synthetic CT for dosimetric monitoring of combined conventional radiotherapy and lattice boost in large lung tumors

Items

Dosimetry parameters

LRT

CRT

LRT + AD

CRT + AD

P-value

Lungs-GTV

Dmean (Gy)

0.97 ± 0.02

3.53 ± 0.34

10.36 ± 7.17

12.73 ± 1.85

0.010*

 V5 (%)

1.01 ± 0.10

21.86 ± 5.73

43.10 ± 19.25

61.56 ± 5.14

< 0.001*

 V10 (%)

0.00 ± 0.00

11.18 ± 3.16

34.36 ± 16.92

48.90 ± 4.47

< 0.001*

 V15 (%)

0.00 ± 0.00

4.94 ± 0.93

22.25 ± 15.26

28.27 ± 5.54

0.001*

 V20 (%)

–

–

15.66 ± 11.52

21.82 ± 3.14

< 0.001*

 V30 (%)

–

–

9.62 ± 7.36

12.63 ± 1.29

< 0.001*

Heart

Dmean (Gy)

1.04 ± 0.64

2.84 ± 1.07

9.16 ± 6.04

10.34 ± 4.86

0.021*

Spinal cord

Dmax (Gy)

5.54 ± 1.22

12.02 ± 1.98

32.44 ± 6.37

40.41 ± 5.11

0.007*

  1. AD denoted the accumulated dose delivered in CRT mode for the initial 20 fractions, each prescribed at 2 Gy